Automatic Surface Tensiometer, DyneMaster DY-700
51,850.00 51,850.00 51850.0 USD
High-end surface tensiometer that performs measuring dynamic contact angle and powder contact angle, lamella length and liquid density in addition to surface/interfacial tension.

>Features:
-Fully automatic operation by single command button
-Built-in stirrer functions in the stage
-Dynamic contact angle (advancing/receding angle) measurement by Wilhelmy method (Option of DY-700)
-Powder contact angle measurement to evaluate wetting phenomena of powder samples (Option of DY-700/500))
-Lamella length measurement
-Liquid density measurement by pycnometer

>Typical applications:
-Dynamic contact angle for evaluating coating properties
-Powder contact angle for evaluating wettability, dispersiveness of powder sample
-Lamella length for evaluating foaming stability of coating agents

>System Includes:
Main body built in thermometer, jacket type stage, magnetic stirrer and built-in calibration system with Platinum plates (x2), Glass lab dishes for surface tension (x2), built in Level, Alcohol lamp, Forceps, and Operation manual.

>Software Included:
-Main DYNALYZER Software for performing all basic operations including surface and interfacial tension tests.
-DYNALYZER add-in Powder measurement software
-DYNALYZER add-in Dynamic contact angle measurement software

>Measurement methods: Surface/Interfacial tension, Dynamic contact angle, Powder contact angle & wetting speed, Lamella length measurement, Liquid density measurement (Pycnometer)
>Measurement range of S.T.: 0~100 mN/m (balance capacity & displaying range: 0~1000mN/m
>Measurement accuracy: 0.02 mN/m
>Resolution: 0.01 mN/m
>Stage speed, stroke: 0.002~50 mm/s, 50mm
>Standard measurement unit: platinum plate
>Optional measurement unit & kit: Platinum DuNouy Ring, Density measurement kit, Dynamic contact angle measurement kit, Powder contact angle measurement kit
>Measurement temperature: Ambient ~ 150 degree C (Heater type), 10~70 degree C (jacket type)
>External Dimensions: 295(W) x 415(D) x452(H) mm
>Weight: about 23kg
>Electric power: AC100-240~50/60Hz


Evaporator for Ores
24,000.00 24,000.00 24000.0 USD
ADP-512 High Heat Evaporator for Ores for Karl Fischer

[Features]
1) Measurement for micro amount of water is least affected from ambient moisture because the movement of
sample boat is controlled by magnet, operated outside the sealed heating unit, and thus accurate and reliable
results are assured.
2) The newly designed electric furnace operates in a wide range of degrees from room temperature up to 1000°C,
featuring relatively short warm-up time, taking approximately 30 minutes for temperature rise as well as for
equilibrium respectively.
3) PID control by the built-in thermostat provides an accurate and stable oven temperature.
4) The safety while working on the electric oven is secured because the maximum temperature over the oven
surface is always kept under 70°C.
5) The built-in excessive heat prevention unit is another safety measures with a thermometer in it, which is
separate from the sensor for temperature control.
6) This evaporator is equipped with two types of electric furnace (for low temperature and for high temperature),
which enables measurement for hygroscopic water as well as combined water without taking the sample out
of the oven.
KCHD-502H Multiple Sample Changer w/Heat Option
19,000.00 19,000.00 19000.0 USD
CHD-502H Multiple Sample Changer with a w/Heating Option and integrated DCU-551 auto cleaning and sampling unit.

The CHD-502 multiple sample changer is used in combination with the density meter DA-600 series. A maximum of 30 samples in each 20mL vial can be set on a carousel. This sampler provides when connected to a density meter a series of events in sequence including cleaning and drying the sample line up to the measuring cell.

H-Type: For the measurements on a sample with a higher softening point, both the turntable unit and the sampling path can be heated and kept warm – the H-type option for heating the turntable unit with an electric heater up to 80°C.

Features:
- Adoption of a peristaltic pump allows an operator to measure the density on a higher viscous sample of 30,000 mPa•s
- The sequential program automatically stops when the unit detects an empty vial position after the last sample vial is finished.
- This unit is equipped with a self-diagnostic function by checking the sequence program, keypad function, and display.
- The auto-power off functions when a series of measurements is finished so that it saves electricity when operated overnight unattended. This feature can be set in while the unit is being activated.
- The cleaning efficiency is increased by blending air into the rinse solvent. By this way, the total amount of rinse solvent is decreased and saved. In addition, not only inside but outside of the nozzle can be cleaned very well since the rinse solution is fed from the outside of the nozzle unit.
- Expensive sample materials like perfume or fragrance can be returned back to sample vial after measurement are over.
-This unit is conformed to CE-mark for safety and noise regulation.

Specifications:
- Number of vials: Up to 30 (20mL vials)
- Minimum sample required: 10mL
- Sample position: Turntable system
- Sampling method: Pressurizing by Peristaltic pump
- Setting Temperature: Room Temp. ~ 80°C
- Heating and cooling system: By electric heater
- Drain System: Sample-returning to vial system

- Program Sequence:
1) Sample measurement only
2) Sample measurement after the "Air & Water" calibration
3) Sample measurement after the "Two kinds of Standard liquids" calibration

-Control:
1) Auto-start by [Meas.] key of density / specific gravity meter or concentration meter
2) Auto-start by [Start.] key of CHD-502 unit
3) Rinsing and purging
4) Auto-calibration by [Calib.] key of density / specific gravity meter or concentration meter
5) Priority measurement

-Display: 20 digits by 2 lines LCD with a backlight

-External communication:
1) Simplified serial interface via the connecting cable (980303388)
2) RS-232C interface for communications

-Ambient Temperature: 1) Temperature: 5 ~ 35°C ; 2) Humidity: less than 85%RH (No condensation)
-Power consumption: Max.760W (NRP40W)
-Dimensions: 582(W) x 445(D) x 392(H) mm
-Weight: Approx. 17kg
KDCU-551H Auto Cleaning and Sampling Unit
16,271.00 16,271.00 16271.0 USD
KDCU-551H Auto Cleaning and Sampling Unit with a heater option (Room Temp. ~ 80°C)

- Model name: DCU-551 Auto Clean and Sampling Unit
- Type: Standard and Small size sampling
- Sample vial: 20mL vial and or 8mL vial
- Required sample: 10mL and 5mL (General-purpose concentration meter : 6mL)

- Sampling method: Pressurizing
1) Drain sample by pressurized pumping
2) Return a sample by the sample-back system

- Drain method
1) Drain sample by pressurized pumping
2) Return a sample by the sample-back system

-Control
1) Auto start with [Meas.] key on a measuring unit
(General-purpose concentration meter, Density/specific gravity meter or Refractometer)
2) Auto start with [Start] key on the Main unit
3) Rinse and purge
4) Auto calibration with [Calib.] key on a measuring unit
(General-purpose concentration meter, Density/specific gravity meter, Refractometer)

-Display: 20 digits by 2 lines LCD with a backlight

-External communication: With a measuring unit: Simplified serial interface With a unit in general: RS-232C × 1 ch.

-Ambient conditions
Temperature : 5 to 35°C (Note: When the ambient temperature is below 15°C, use Acetone for “Rinse 2” solution)
Humidity : Below 85%RH (subject no condensation)

-Power Source: AC 100-120 / 200-240 V ±10%, 50/60 Hz
-Power Consumption: Max. 760W (Main unit Approx. 40W)
-Dimensions: W(291) × D(310) × H(342) [mm]
-Weight: Approx. 10kg
-CE marking: EMC : EN61326 LVD : EN61010-1 conformed
For Metal cleaning acid & ferrous concentrations
15,625.00 15,625.00 15625.0 USD
DCM-101
KCHD-502N Multiple Sample Changer
14,200.00 14,200.00 14200.0 USD
KCHD-502N Multiple Sample Changer

Features
• Adoption of a peristaltic pump allows an operator to measure the density on higher viscous sample of 30,000 mPa•s
• The sequential program automatically stops when the unit detects an empty vial position after the last sample vial is finished.
• This unit is equipped with self-diagnostic function by checking sequence program, keypad function, and display.
• The auto-power-off functions when a series of measurements is finished so that it saves electricity when operated overnight unattended. This feature can be set in while the unit is being activated.
• The cleaning efficiency is increased by blending air into rinse solvent. By this way, the total amount of rinse solvent is decreased and saved. In addition, not only inside but outside of the nozzle can be cleaned very well since the rinse solution is fed from the outside of the nozzle unit.
• Expensive sample materials like perfume or fragrance can be returned back to sample vial after measurement are over.
• The CHD-502 series provides a variety of models with different specifications depending on what type of sample material is going to be measured : N type for room temperature used, SS type for small size sampling, H type for high temperature or C type for low temperature used.

Type name: Standard type N
Number of vials: Up to 30 (20mL vial)
Min. sample required: 10mL
Sample position: Turntable System
Sampling method: Pressurizing by peristaltic pump
Drain system: 1) Pressurized draining 2) Sample-returning to vial system
Program sequence: 1) Sample measurement only 2) Sample measurement after the "Air & Water" calibration 3) Sample measurement after the "Two kinds of Standard liquids" calibration
Control: 1) Auto-start by [Meas.] key of density / specific gravity meter or concentration meter 2) Auto-start by [Start.] key of CHD-502 unit 3) Rinsing and purging 4) Auto-calibration by [Calib.] key of density / specific gravity meter or concentration meter 5) Priority measurement
Display: 20 digits by 2 lines LCD with a backlight
Ext. communications: 1) Simplified serial interface via the connecting cable (980303388) 2) RS-232C interface for communications
Ambient condition: 1) Temperature: 5 ~ 35°C ; 2) Humidity: less than 85%RH (No condensation)
Dimension: 582(W) x 445(D) x 392(H) mm
Weight: Approx. 17kg
Density/Specific Gravity Meter
13,900.00 13,900.00 13900.0 USD
ASTM D1250,D1475,D4052,D4806,D5002,D5798,D5931

Quickest measurement in 20 seconds Minimum sample of 1.0 mL
Viscosity correction for high-viscosity samples*1 Touchscreen operation
Comes with Density Standard Liquid Equipped with sampling*2 & dry pump Completely ready for use Customizable display & sound
Easy operation & maintenance-free

-Measurement Range; 0 ~ 3 g/cm3
-Temperature Range; 0 ~ 96°C (32 ~ 204.8°F)
-Accuracy; Density ±1x10-4 g/cm3 (0.0001 g/cm3)/ temperature ±0.05 °C (±0.09 °F)
-Repeatability; SD 5x10-5 g/cm3
-Min sample required; Approx. 1 mL (Syringe) / Approx. 2mL (Pump)
-Measurement time; to 4 mins (Manual) / 2 to 10 mins (Auto)
-Resolution; Density & SG 0.0001/ temperature 0.01
-Viscosity Correction: YES
-Method; Saves up to 100 different methods in built-in memory
-Data I/O; USB flash drive as data storage medium, app notes provided in USB flash drive
-Dimensions; 320 (W) x 365 (D) x 250 (H) mm (12.6 (W) x 14.4 (D) x 9.8 (H) inches)
-Weight; 18 kg (39.7 lbs)
Evaporator (KF-610 series)
11,299.00 11,299.00 11299.0 USD
ADP-611 Evaporator

The ADP-611 is an evaporator/oven to be used and connected with a KF moisture titrator for moisture testing of solid samples, powder samples or samples that may interfere by side reaction if titrated by direct injection method.

SPECIFICATIONS:
-Type and model; Model ADP-611 Evaporator
-Heating method; Electrically conductive clear heater glass
-Temperature range; Control method: proportional
Setting range: 50 ~ 300°C Minimum temperature setting: 1°C
Temperature precision: ± 2°C
Temperature sensor: K-thermocouple
-Temperature display: LED digital 3 characters
-Heater unit : Pyrex glass tube φ 30 × 335mm
-Sample boat: Pyrex glass 68 L × 25 W × 15 H mm , Capacity 16mL
-Carrier gas: Nitrogen: not included in supplied parts./ Nitrogen gas, regulator, and tubing have to be prepared by user
-Gas dryer: Zeolite 100g 2 pcs
-Gas flow: 100 ~ 300 mL/min
-Dimension: 370 (W) × 195 (D) × 217 (H) mm
-Power: AC100 ~ 120V± 10% 50Hz/60Hz / AC220 ~ 240V± 10% 50Hz/60Hz (Pre-adjusted before shipment from the factory)
-Power Consumption: Approx. 300W
Weight: Approx. 5kg
Low Heat Flow/Embedding Type
11,111.11 11,111.11 11111.11 USD
KTC-C: Low Heat Flow/Embedding Type
Low Heat Flow/Embedding Type
11,111.11 11,111.11 11111.11 USD
KTC-B: Low Heat Flow/Embedding Type
KDCU-551N Auto Cleaning and Sampling Unit
10,847.00 10,847.00 10847.0 USD
KDCU-551N Auto Cleaning and Sampling Unit
Refractometer
10,550.00 10,550.00 10550.0 USD
RA-620 Benchtop Refractometer

Specs:

-Measuring Method: Detection of Critical Angle of Optical Refraction
-Light Source: LED Na-D Line (589.3nm)
-Measuring Range: Refractive Index (nD)=1.3200 ~ 1.58000,
Brix=0.00 ~ 100.00%
-Accuracy *1:Refractive Index (nD)=±0.00002,Brix=±0.014%(0~85%)
-Repeatability *2:Refractive Index (nD)=±0.00001,Brix=±0.01%
-Resolution:Refractive Index (nD)=0.00001,Brix=0.01%
-Temperature Control:Peltier Thermostat 5 ~ 75°C *3
-Temperature Indication Resolution:0.01°C
-Minimum Amount of Sample: 0.2mL
-Display:4.7-inch Backlit Colour LCD
-Operation:Touch Screen
-Security:Password Protection
-Data Storage: # of methods=100,Measurement results=up to 300, calibration record=up to 20,Check Record=up to 20, External Storage=USB Flash Drive
-Temperature Compensation: Brix=5.00 75.00 (Automatic compensation by preprogrammed conversion table.)
-Interfaces: LAN, USB1.1,RS-232
-Power Supply:AC 100~240 V, 50/60 Hz (AC adapter supplied with instrument.)
-Dimensions:191(W)×281(D)×161(H)mm
-Weight:5Kg
KEM Sample Changer, 12 Samples
10,150.00 10,150.00 10150.0 USD
KCHG-310-12: KEM Sample Changer, 12 Samples
Multi-Channel Heat Flow Meter
9,987.00 9,987.00 9987.0 USD
HFM-215 Multi-Channel Heat Flow Meter

-Connectable with all heat flow sensors
-3.5 inch color TFT LCD
-High capacity external memory: Internal memory (16MB) can store data of 55 hours when eight sensors of sensor constant A/B type are connected and sampling rate is set at one second. External memory media, compact flash or SD card (1 to 2 GB), enable continuous measurement.
-Equipped with Ethernet: Ethernet (10BASE-T/100BASE-TX) enables data collection through network
-Data communication: Equipped with e-mail transmitting, Web server, FTP server and FTP client functions. RS-485, RS-232C and USB communication devices can also be used.
-Dual power source: Both rechargeable battery and AC adapter can be used, making the HFM-215N compact and easy to carry. Batter life for continuous use is seven hours (may vary depending on conditions).
-Enhanced safety: Equipped with shock-resistant rubber cushions.
11 Position Sample Changer
9,900.00 9,900.00 9900.0 USD
CHA-700-11 : Automatic Titrator Multiple Sample Changer (11 sample)
For Water Cooled Surface Heavy Duty
9,629.63 9,629.63 9629.630000000001 USD
KTV-C: For Water Cooled Surface Heavy Duty
For Water Cooled Surface Heavy Duty
9,629.63 9,629.63 9629.630000000001 USD
KTV-B: For Water Cooled Surface Heavy Duty
Refactometer
8,990.00 8,990.00 8990.0 USD
RA-600 Benchtop Refractometer

Specs:

-Measuring Method: Detection of Critical Angle of Optical Refraction
-Light Source: LED Na-D Line (589.3nm)
-Measuring Range: Refractive Index (nD)=1.3200 ~ 1.7000,
Brix=0.00 ~ 100.00%
-Accuracy *1:Refractive Index (nD)=±0.0001,Brix=±0.1%
-Repeatability *2:Refractive Index (nD)=±0.0001,Brix=±0.1%
-Resolution:Refractive Index (nD)=0.0001,Brix=0.10%
-Temperature Control:Peltier Thermostat 5 ~ 75°C *3
-Temperature Indication Resolution:0.1°C
-Minimum Amount of Sample
-Display:4.7-inch Backlit Colour LCD
-Operation:Touch Screen
-Security:Password Protection
-Data Storage: # of methods=100,Measurement results=up to 300, calibration record=up to 20,Check Record=up to 20, External Storage=USB Flash Drive
-Temperature Compensation: Brix=5.00 75.00 (Automatic compensation by preprogrammed conversion table.)
-Interfaces: LAN, USB1.1,RS-232
-Power Supply:AC 100~240 V, 50/60 Hz (AC adapter supplied with instrument.)
-Dimensions:191(W)×281(D)×161(H)mm
-Weight:5Kg
Evaporator (for Karl Fischer testing heavy Oil)
8,850.00 8,850.00 8850.0 USD
ADP-513 Karl Fischer Oil Evaporator

FEATURES:
-Digital temperature control
-Rotameter carrier gas flow control
-Built-in carrier gas drying system Operating temperature ambient up to 200°C Heated transfer tube
-Overheating protection
-Automatic cell evacuation system

SPECIFICATIONS:
Temperature Range: Room - 200°C
Heating method: Cartridge base heater
Ambient conditions: 5 - 35°C, less than 85% RH
Power: AC 200-240, 50/60Hz
Power Consumption: 400W
Dimensions: 320 x 210 x 330 mm
Weight: Approx. 6 kg
KEM Particle Analyzer
8,820.00 8,820.00 8820.0 USD
PCD-500