Evaporator for Ores
24,000.00 24,000.00 24000.0 USD
ADP-512 High Heat Evaporator for Ores for Karl Fischer

[Features]
1) Measurement for micro amount of water is least affected from ambient moisture because the movement of
sample boat is controlled by magnet, operated outside the sealed heating unit, and thus accurate and reliable
results are assured.
2) The newly designed electric furnace operates in a wide range of degrees from room temperature up to 1000°C,
featuring relatively short warm-up time, taking approximately 30 minutes for temperature rise as well as for
equilibrium respectively.
3) PID control by the built-in thermostat provides an accurate and stable oven temperature.
4) The safety while working on the electric oven is secured because the maximum temperature over the oven
surface is always kept under 70°C.
5) The built-in excessive heat prevention unit is another safety measures with a thermometer in it, which is
separate from the sensor for temperature control.
6) This evaporator is equipped with two types of electric furnace (for low temperature and for high temperature),
which enables measurement for hygroscopic water as well as combined water without taking the sample out
of the oven.
Evaporator (KF-610 series)
11,299.00 11,299.00 11299.0 USD
ADP-611 Evaporator

The ADP-611 is an evaporator/oven to be used and connected with a KF moisture titrator for moisture testing of solid samples, powder samples or samples that may interfere by side reaction if titrated by direct injection method.

SPECIFICATIONS:
-Type and model; Model ADP-611 Evaporator
-Heating method; Electrically conductive clear heater glass
-Temperature range; Control method: proportional
Setting range: 50 ~ 300°C Minimum temperature setting: 1°C
Temperature precision: ± 2°C
Temperature sensor: K-thermocouple
-Temperature display: LED digital 3 characters
-Heater unit : Pyrex glass tube φ 30 × 335mm
-Sample boat: Pyrex glass 68 L × 25 W × 15 H mm , Capacity 16mL
-Carrier gas: Nitrogen: not included in supplied parts./ Nitrogen gas, regulator, and tubing have to be prepared by user
-Gas dryer: Zeolite 100g 2 pcs
-Gas flow: 100 ~ 300 mL/min
-Dimension: 370 (W) × 195 (D) × 217 (H) mm
-Power: AC100 ~ 120V± 10% 50Hz/60Hz / AC220 ~ 240V± 10% 50Hz/60Hz (Pre-adjusted before shipment from the factory)
-Power Consumption: Approx. 300W
Weight: Approx. 5kg
Evaporator (for Karl Fischer testing heavy Oil)
8,850.00 8,850.00 8850.0 USD
ADP-513 Karl Fischer Oil Evaporator

FEATURES:
-Digital temperature control
-Rotameter carrier gas flow control
-Built-in carrier gas drying system Operating temperature ambient up to 200°C Heated transfer tube
-Overheating protection
-Automatic cell evacuation system

SPECIFICATIONS:
Temperature Range: Room - 200°C
Heating method: Cartridge base heater
Ambient conditions: 5 - 35°C, less than 85% RH
Power: AC 200-240, 50/60Hz
Power Consumption: 400W
Dimensions: 320 x 210 x 330 mm
Weight: Approx. 6 kg
Water activity meter /LabTouch-aw (basic)
7,950.00 7,950.00 7950.0 USD
Laboratory instrument WITH TOUCH-SCREEN for water activity measurement in foodstuff, drugs and cosmetic products.

-Measurement range aw : 0.06 ... 0.97aw, (non condensing)
-Measurement range temp. : 5 ... 45°C
-Sensor : with resistive-electrolytic measurement cell CM-2
-Instrument accuracy : +/- 0.005 aw, +/- 0.15K
-Communication : RS-232, USB 2x RS-485 for add. chambers SD card -> PC (NovaLog MC)

LabTouch-aw includes:
Dimensions : 200 x 300x 95 mm
Weight : 2.800 kg
 Measurement device LabTouch
 External universal power supply
 SD card 2GB Memory
 4 SAL-T: 33, 58, 75, 84% RH
 40 sample dishes ePW
 Spare pre-filters white (5 pcs)
 Tension ring
 Operating instructions
 Factory certificate of 7-point calibration, 11-33-58-75-84-90-97%
Volumetric Karl Fischer Titrator
7,850.00 7,850.00 7850.0 USD
MKV-710B Volumetric Karl Fisher Titrator

Specifications:
-Type: Volumetric Karl Fischer Moisture Titrator

-Model: MKV-710B

-Product configuration: MKV-710+ Manual Solvent Change Unit.

-Measuring method: Karl Fischer Volumetric Titration

-Measuring range:
1. Water content: 0.1 to 500mgH2O (depends on KF reagent factor)
2. 10ppm to 100%H2O

-Burette precision: Volume: 10mL burette, Discharge precision: ±0.015mL repeatability, Repeatability: ±0.005mL

-Endpoint detection: By polarized potential level detected with a twin platinum electrode

-Titration form: Normal titration / Back titration (Option additional burette required)

-Required solvent: 30 to100mL (in S-type titration vessel)

-Methods: 20

-Key Operation: Sheet key on main unit

-Display:
1. White LED-backlit LCD
2. English / Japanese / Mandarin Chinese / Korean / Russian / Spanish
3. 1-channel display

-Calculation: Concentration of water content, statistics data processing (mean, SD and RSD) and automatic averaging of blank value and factor value

-Data storage: 100 samples

-GLP conformance: 􏰄registration of operator / 􏰅Record of check results/ Record of factor measurement / Management of conduction time

-External I/O:
1. RS232C port × 2 (for Dot matrix printer, Electronic balance, Data Capture Software (SOFT-CAP)
2. USB x 1 (for USB flash drive, thermal printer, Keyboard, Barcode reader, Foot switch, USB HUB, Android device)
3. SS-BUS x 1 (for APB)

-Extensibility
1. Automatic piston burette: Can control max 2 burette drives (including two built-in burette drives)

-Ambient Condition:
1. Temperature; 5 to 35°C
2. Humidity; 85%RH or below (no condensation)

-Power Source: AC100 - 240 ±10% 50/60 Hz

-Power Consumption: Main unit; Approx. 20W, Printer; Approx. 7W

-Dimensions:
1. Titration Unit; 141(W) × 292(D) × 367(H) mm (, not incl. tubing)
2. Stirrer; 107(W) × 206(D) × 322(H) mm (not incl. Solvent Change unit)
3. Solvent Change Unit; 240(W) × 140(D) × 400(H) mm (not incl. tubing)
4. Printer; 106(W)× 180(D) × 88(H) mm

-Weight:
1. Titration Unit = 4.0kg,
2. Stirrer = 2.0kg,
3. Solvent Change Unit = 0.6kg,
4. Printer = 0.4kg

-Conformity Standard: CE marking EMC : EN61326-1 LVD: EN61010-1 RE Directive Burette unit EBU FCC Part15 SubpartC FCC ID: 2ABSVEBU01
Coulometric Karl Fischer Titrator
7,850.00 7,850.00 7850.0 USD
MKC-710B Coulometric Karl Fisher Titrator
-Measuring Range; Water content / Bromine index: 10ug to 300mg
-Measurement cell; 2-Component or 1-Component
-Precision; Relative standard deviation : less than 0.3% (n=10) *Per KEM standard measurement conditions and standard liquids
-Display resolution; 0.1ug
-Methods; 20
-Data storage; 100 samples
-External I/O; -232C port × 2 (for printer, balance, software), USBx1 (for USB flash drive, printer, keyboard, barcode reader, foot switch, USB hub, Android device)
-Ambient Condition; (1) Temperature: 5 to 35°C (2): 85% H or below (no condensation)
-Power Source; AC100 - 240 ±10% 50/60 Hz
-Dimensions; 141(W ) × 292(D) × 244(H) mm
-Weight; Approx.3.0kg
-GLP Conformance; Registration of operator / Check performance with standard substance / reagent life control / Management of conduction time
-Conformity Standard; CE marking EMC: EN61326-1 L D: EN61010-1
Aquapal III Moisture Analyzer w/ Standard Glassware
7,850.00 7,850.00 7850.0 USD
Aquapal III Moisture Analyzer W/ Standard Glassware:
Coulometric Titrator Standard Glassware Tests according to ASTM D4928, D1533, D1744, and equivalent methods. CE approved Manufacturer.

Unit ready for operation includes:

- Built-in printer with standard paper that backs up a test with hard copy results.
- Verify test at any time with printout including mean, standard deviation and coefficient of variation.
- Speed is 2 mg/minute
- Test range from 1ppm to 100%
- Sensitive to 0.1 ug
- Calculations in Weight, volume or dilution
- Automatic Drift Correction
- Results printed in ppm -% - ug
- Standard RS232C output
- Small lab foot print 14" x 8"
- Portable (field Use)
Aquapal III Moisture Analyzer w/ Single-reagent Glassware
7,800.00 7,800.00 7800.0 USD
Aquapal III Moisture Analyzer W/ Single Reagent Glassware: Coulometric Titrator Diaphramless Glassware Tests according to ASTM D4928, D1533, D1744 and equivalent methods. CE approved Manufacturer. unit ready for operation, includes: - Built in printer with standard paper that backs up test with hard copy results. - Speed is 2 mg/minute - Test range from 1ppm to 100% - Sensitive to 0.1 ug - Calculations in Weight, volume or dilution - Automatic Drift Correction - Results printed in ppm ,% , ug - Standard RS232C output - Small lab foot print 14" x 8" - Portable (field Use) *Easy to use for non-technical operators - Simple keypad format with limited menus. Enter the weight or Specific gravity number, Press <ENTER>, Introduce sample, and press <START>. When the test finishes data showing the results will printout automatically.
Touch Panel Controller
7,457.00 7,457.00 7457.0 USD
MCU-610 Touch Panel Controller for Titrator
Water activity meter /LabSwift-aw (w/battery)
4,800.00 4,800.00 4800.0 USD
The built in Lithium-Ions rechargeable battery allows mobile measurements. The set is delivered with a plastic carrying case including accessories. A SD-card interface enables the transfer of all measurement data to a PC or printer.

-Measurement range aw : 0.11 ... 0.90aw, (non condensing)
-Measurement range temp. : 5 ... 45°C
-Sensor : with resistive-electrolytic measurement cell CM-2
-Instrument accuracy : +/- 0.01 aw, +/- 0.15K
-Communication : SD card -> PC

LabSwift-aw set consisting of :
 Measurement device LabSwift-aw
 External universal power supply
 Battery incl. electronics (built in)
 SD card
 3 SAL-T: 11, 58, 84% RH
 40 sample dishes ePW
 Spare pre-filters white (5 pcs)
 Tension ring
 Operating instructions
 Factory certificate of 6-point calibration, 11-33-58-75-84-90%
Weight : 3.100 kgs

Digital Moisture Balance
4,480.00 4,480.00 4480.0 USD
The Digital Moisture Balance is rugged, accurate and simple to use. Because of this versatility, it is being used in both the laboratory and the production floor. Some of the specific operating features include: -Three operational modes -Sample sizes from a few grams to 100 grams -Results to +/- 0.2 % moisture -Readouts in grams (g) - % moisture - % solids - % dry weight -On-site calibration checks with the included calibration weight -Printer ready To run a test, the operator presses the tare button, loads the sample, closes the cover and presses the start button. The testing procedure is that simple; operators can be trained in minutes
KEM Amenity Meter
4,312.00 4,312.00 4312.0 USD
AM-101
Liquefied gas sampler/MKC
3,345.52 3,345.52 3345.52 USD
K433-3389: Liquefied gas sampler/MKC, MKA

Parts Included:
(1) Connecting pipe12-05241
(2) Needle 66-00196
(3) Sampling cock 12-05144
(4) Exhaust tube 􏰓 Desiccator 12-04306 (not for MKC)
(5) Bubbler 20-09225
(6) Bubbler adapter 20-09226 (not for MKA)
(7) Stopper with septum 98-433-0062
(8) PTFE Packing 20-05723
(9) Stand, Clamp, Clamp holder 98-433-0063
(10) Desiccant Container 12-05333 (not for MKA)
(11) Silicone grease 12-04181
(12) Liquefied gas sampler Operation Manual 59-00427
1Component Type Titration Cell Unit with Funnel
3,297.72 3,297.72 3297.7200000000003 USD
1Component Type Titration Cell Unit with Funnel
2Component Type Titration Cell Unit
3,248.00 3,248.00 3248.0 USD
K120735501(12-006-6100-48) (K433-0005): Karl Fisher Cell Unit; For two solution system; Includes Titration cell, Inner buret (2-solution), Twin Platinum detector electrode and other attachment
1Component Type Titration cell unit
3,245.00 3,245.00 3245.0 USD
Titration cell unit complete with 1component inner burette, detector electrode, port plus, and stir bar
Liquefied gas sampler/MKA
3,106.55 3,106.55 3106.55 USD
K433-3014: Liquefied gas sampler/MKA
Water activity meter /LabStart-aw
3,050.00 3,050.00 3050.0 USD
Portable low cost precision instrument for water activity measurement (aW) in foodstuff and powder products.
This compact low cost water activity measurement device is intended for a mobile measurement directly at-line and has been developed for standard applications and for users, who want to start with the water activity measurement. The LabStart-aw is delivered including all necessary accessories.

-Measurement range aw : 0.20 ... 0.80aw
-Measurement range temp. : 15 ... 30°C (Sample +/-5°C over ambient)
-Sensor : with resistive-electrolytic measurement cell CM-4
-Instrument accuracy : +/- 0.03 aw +/- 0.3K

LabStart-aw set consisting of :
 Measurement device LabStart-aw
 External universal power supply
 1 SAL-T: 75% RH
 25 sample dishes ePW
 Spare pre-filters white (5 pcs)
 Tension ring
 Factory certificate of 2-point calibration 33% and 75% RH
Weight : 1.500 kgs
Dimensions: 85x140x225mm (HxWxL)
Heat Extractor for Sugar Samples
2,985.00 2,985.00 2985.0 USD
ADP-344; Heat Extractor for Sugar Samples
Homogenizer attachment
2,927.33 2,927.33 2927.33 USD
K433-0085: Homogenizer attachment